A2L Air-Cooled Scroll Process Chillers
Air-cooled scroll process chillers, by far, are the most common applications for process duty service. These chillers remove heat from your process and reject that heat to the outdoor air. Air-cooled process chillers tend to be easier and less expensive to service, cost less than water-cooled process chillers, and offer a wide variety of options (such as economizers), providing excellent design flexibility.
Available as packaged chiller systems or split-systems (outdoor condenser, indoor chiller). Perfect for any location, climate, and application. Our wide range of unit sizes can be used for a variety of residential, commercial, or industrial cooling solutions.
Now Available in R454A and R454C, these units comply with the A2L listings for refrigerants that meet modern environmental standards. R454A and R454C refrigerants are both low in toxicity and low in flammability for an efficient and safe future.


Standard Features:
[1] denotes optional items on most competing brands.
Available Options:
Click on a chiller model below to download a spec sheet.
R454C
Tankless Packaged, Single, Dual, and Quad Circuit Scroll
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressor | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| PZA1S | 11,700 | 36 | 34 | 44 | 260 | 1 | 1.0 |
| PZA2S | 23,700 | 36 | 34 | 44 | 265 | 1 | 2.0 |
| PZA3S | 35,500 | 36 | 34 | 44 | 450 | 1 | 3.0 |
| PZA3.5S | 41,100 | 36 | 34 | 44 | 475 | 1 | 3.5 |
| PZA4.5S | 51,700 | 46 | 34 | 48 | 490 | 1 | 4.5 |
| PZA5S | 57,900 | 46 | 34 | 48 | 500 | 1 | 5.0 |
| PZA5.5S | 61,500 | 46 | 34 | 48 | 500 | 1 | 5.0 |
| PZA6S | 77,500 | 75 | 34 | 50 | 650 | 1 | 6.0 |
| PZA7S | 88,400 | 75 | 34 | 50 | 650 | 1 | 7.0 |
| PZA9S | 107,000 | 75 | 34 | 50 | 690 | 1 | 9.0 |
| PZA11S | 132,000 | 75 | 34 | 50 | 750 | 1 | 11.0 |
| PZA12S | 149,500 | 75 | 34 | 50 | 800 | 1 | 12.0 |
| PZA7D | 82,200 | 75 | 34 | 50 | 875 | 2 | 3.5 |
| PZA9D | 103,400 | 75 | 34 | 50 | 900 | 2 | 4.5 |
| PZA10D | 115,800 | 75 | 34 | 50 | 950 | 2 | 5.0 |
| PZA11D | 123,000 | 75 | 34 | 50 | 950 | 2 | 5.5 |
| PZA13D | 155,000 | 85 | 40 | 50 | 985 | 2 | 6.5 |
| PZA15D | 176,800 | 85 | 40 | 50 | 1000 | 2 | 7.5 |
| PZA18D | 214,000 | 85 | 40 | 50 | 1000 | 2 | 9.0 |
| PZA22D | 264,000 | 75 | 66 | 51 | 1150 | 2 | 11.0 |
| PZA25D | 299,000 | 230 | 45.5 | 55 | 2600 | 2 | 12.5 |
| PZA14M | 164,400 | 176.5 | 45.5 | 55 | 3300 | 4 | 3.5 |
| PZA18M | 206,800 | 176.5 | 45.5 | 55 | 3400 | 4 | 4.5 |
| PZA22M | 246,400 | 176.5 | 45.5 | 55 | 3490 | 4 | 5.5 |
| PZA26M | 310,400 | 176.5 | 45.5 | 55 | 3550 | 4 | 6.5 |
| PZA30M | 353,600 | 176.5 | 88 | 55 | 4800 | 4 | 7.5 |
| PZA36M | 428,000 | 176.5 | 88 | 55 | 4800 | 4 | 9.0 |
| PZA44M | 528,000 | 176.5 | 88 | 55 | 5100 | 4 | 11.0 |
| PZA50M | 630,000 | 176.5 | 88 | 55 | 5100 | 4 | 12.5 |
Packaged, Single & Dual Circuit Scroll, with Stainless Steel Tank
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressors | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| PZAT1S | 10,950 | 36 | 34 | 68 | 550 | 1 | 1.0 |
| PZAT2S | 22,300 | 36 | 34 | 68 | 650 | 1 | 2.0 |
| PZAT3S | 33,300 | 36 | 34 | 68 | 800 | 1 | 3.0 |
| PZAT3.5S | 38,500 | 36 | 34 | 68 | 825 | 1 | 3.5 |
| PZAT4.5S | 48,600 | 46 | 34 | 74 | 850 | 1 | 4.5 |
| PZAT5S | 54,400 | 46 | 34 | 74 | 875 | 1 | 5.0 |
| PZAT5.5S | 57,800 | 46 | 34 | 74 | 900 | 1 | 5.5 |
| PZAT6S | 72,800 | 75 | 34 | 76 | 1100 | 1 | 6.0 |
| PZAT7S | 83,000 | 75 | 34 | 76 | 1125 | 1 | 7.0 |
| PZAT9S | 100,500 | 75 | 34 | 76 | 1150 | 1 | 9.0 |
| PZAT11S | 123,500 | 75 | 34 | 76 | 1300 | 1 | 11.0 |
| PZAT12S | 141,000 | 75 | 34 | 76 | 1400 | 1 | 12.0 |
| PZAT7D | 77,000 | 75 | 34 | 76 | 1100 | 2 | 3.5 |
| PZAT9D | 97,200 | 75 | 34 | 76 | 1200 | 2 | 4.5 |
| PZAT10D | 108,800 | 75 | 34 | 76 | 1250 | 2 | 5.0 |
| PZAT11D | 115,600 | 75 | 34 | 76 | 1275 | 2 | 5.5 |
| PZAT13D | 145,600 | 85 | 40 | 76 | 1300 | 2 | 6.5 |
| PZAT15D | 166,000 | 85 | 40 | 76 | 1400 | 2 | 7.5 |
| PZAT18D | 201,000 | 85 | 40 | 76 | 1450 | 2 | 9.0 |
| PZAT22D | 247,000 | 75 | 66 | 76 | 1300 | 2 | 11.0 |
Tankless Split-System, Single, Dual, & Quad Circuit Scroll
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressor | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| IEZA1S | 11,700 | 44 | 28 | 36 | 225 | 1 | 1.0 |
| IEZA2S | 23,700 | 44 | 28 | 36 | 370 | 1 | 2.0 |
| IEZA3S | 35,500 | 44 | 28 | 36 | 500 | 1 | 3.0 |
| IEZA3.5S | 41,100 | 44 | 28 | 36 | 525 | 1 | 3.5 |
| IEZA4.5S | 51,700 | 44 | 28 | 36 | 550 | 1 | 4.5 |
| IEZA5S | 57,900 | 44 | 28 | 36 | 575 | 1 | 5.0 |
| IEZA5.5S | 61,500 | 44 | 28 | 36 | 600 | 1 | 5.5 |
| IEZA6S | 77,500 | 44 | 28 | 36 | 700 | 1 | 6.0 |
| IEZA7S | 88,400 | 44 | 28 | 36 | 725 | 1 | 7.0 |
| IEZA9S | 107,000 | 44 | 28 | 36 | 750 | 1 | 9.0 |
| IEZA11S | 132,000 | 44 | 28 | 36 | 825 | 1 | 11.0 |
| IEZA12S | 157,500 | 44 | 28 | 36 | 850 | 1 | 12.0 |
| IEZA7D | 83,600 | 65 | 30 | 37 | 900 | 2 | 3.5 |
| IEZA9D | 103,400 | 65 | 30 | 37 | 1000 | 2 | 4.5 |
| IEZA10D | 115,800 | 65 | 30 | 37 | 1100 | 2 | 5.0 |
| IEZA11D | 123,000 | 65 | 30 | 37 | 1200 | 2 | 5.5 |
| IEZA13D | 155,000 | 65 | 30 | 37 | 1400 | 2 | 6.5 |
| IEZA15D | 176,800 | 65 | 30 | 37 | 1450 | 2 | 7.5 |
| IEZA18D | 214,000 | 65 | 30 | 37 | 1450 | 2 | 9.0 |
| IEZA22D | 264,000 | 65 | 30 | 37 | 1750 | 2 | 11.0 |
| IEZA25D | 315,000 | 85 | 34 | 42 | 1500 | 2 | 12.5 |
| IEZA14M | 167,200 | 112 | 40 | 42 | 1800 | 4 | 3.5 |
| IEZA18M | 206,800 | 112 | 40 | 42 | 1850 | 4 | 4.5 |
| IEZA22M | 246,000 | 112 | 40 | 42 | 1900 | 4 | 5.5 |
| IEZA26M | 310,000 | 112 | 40 | 42 | 2400 | 4 | 6.5 |
| IEZA30M | 353,600 | 112 | 40 | 42 | 2450 | 4 | 7.5 |
| IEZA36M | 428,000 | 112 | 40 | 42 | 2500 | 4 | 9.0 |
| IEZA44M | 528,000 | 112 | 40 | 42 | 2550 | 4 | 11.0 |
| IEZA50M | 630,000 | 112 | 40 | 42 | 3000 | 4 | 12.5 |
Split-System, Single & Dual Circuit Scroll, with Stainless Steel Tank
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressor | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| IEZAT1S | 10,950 | 36 | 34 | 65 | 550 | 1 | 1.0 |
| IEZAT2S | 22,300 | 36 | 34 | 65 | 650 | 1 | 2.0 |
| IEZAT3S | 33,300 | 36 | 34 | 65 | 800 | 1 | 3.0 |
| IEZAT3.5S | 38,500 | 36 | 34 | 65 | 825 | 1 | 3.5 |
| IEZAT4.5S | 48,600 | 46 | 34 | 69 | 850 | 1 | 4.5 |
| IEZAT5S | 54,400 | 46 | 34 | 69 | 875 | 1 | 5.0 |
| IEZAT5.5S | 57,800 | 46 | 34 | 69 | 900 | 1 | 5.5 |
| IEZAT6S | 72,800 | 75 | 34 | 70 | 1100 | 1 | 6.0 |
| IEZAT7S | 83,000 | 75 | 34 | 69 | 1150 | 1 | 7.0 |
| IEZAT9S | 100,500 | 75 | 34 | 70 | 1250 | 1 | 9.0 |
| IEZAT11S | 123,500 | 75 | 34 | 70 | 1300 | 1 | 11.0 |
| IEZAT12S | 141,000 | 75 | 34 | 70 | 1325 | 1 | 12.0 |
| IEZAT7D | 77,000 | 75 | 34 | 70 | 1350 | 2 | 3.5 |
| IEZAT9D | 97,200 | 75 | 34 | 70 | 1400 | 2 | 4.5 |
| IEZAT10D | 108,800 | 75 | 34 | 70 | 1450 | 2 | 5.0 |
| IEZAT11D | 115,600 | 75 | 34 | 70 | 1500 | 2 | 5.5 |
| IEZAT13D | 145,600 | 75 | 34 | 70 | 1700 | 2 | 6.5 |
| IEZAT15D | 166,000 | 85 | 34 | 70 | 1800 | 2 | 7.5 |
| IEZAT18D | 201,000 | 85 | 34 | 70 | 1900 | 2 | 9.0 |
| IEZAT22D | 247,000 | 85 | 34 | 70 | 2100 | 2 | 11.0 |
R454A
Tankless Packaged, Single, Dual, and Quad Circuit Scroll Chillers
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressor | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| PZA1S | 13,550 | 36 | 34 | 44 | 260 | 1 | 1.0 |
| PZA2.5S | 27,500 | 36 | 34 | 44 | 265 | 1 | 2.5 |
| PZA3.5S | 41,000 | 36 | 34 | 44 | 450 | 1 | 3.5 |
| PZA4S | 48,300 | 36 | 34 | 44 | 475 | 1 | 4.0 |
| PZA5S | 59,600 | 46 | 34 | 48 | 490 | 1 | 5.0 |
| PZA5.5S | 66,800 | 46 | 34 | 48 | 500 | 1 | 5.5 |
| PZA6S | 71,000 | 46 | 34 | 48 | 500 | 1 | 6.0 |
| PZA7S | 92,600 | 75 | 34 | 50 | 650 | 1 | 7.0 |
| PZA8S | 102,500 | 75 | 34 | 50 | 650 | 1 | 8.0 |
| PZA10S | 123,500 | 75 | 34 | 50 | 690 | 1 | 10.0 |
| PZA12S | 152,000 | 75 | 34 | 50 | 750 | 1 | 12.0 |
| PZA15S | 182,500 | 75 | 34 | 50 | 800 | 1 | 15.0 |
| PZA8D | 96,600 | 75 | 34 | 50 | 875 | 2 | 4.0 |
| PZA10D | 119,200 | 75 | 34 | 50 | 900 | 2 | 5.0 |
| PZA11D | 133,600 | 75 | 34 | 50 | 950 | 2 | 5.5 |
| PZA12D | 142,000 | 75 | 34 | 50 | 950 | 2 | 6.0 |
| PZA15D | 185,200 | 85 | 40 | 50 | 985 | 2 | 7.5 |
| PZA17D | 205,000 | 85 | 40 | 50 | 1000 | 2 | 8.5 |
| PZA21D | 247,000 | 85 | 40 | 50 | 1000 | 2 | 11.0 |
| PZA25D | 304,000 | 75 | 66 | 51 | 1250 | 2 | 12.5 |
| PZA30D | 365,000 | 176.5 | 45.5 | 55 | 3550 | 2 | 15.0 |
| PZA16M | 193,200 | 176.5 | 45.5 | 55 | 3300 | 4 | 4.0 |
| PZA20M | 238,400 | 176.5 | 45.5 | 55 | 3400 | 4 | 5.0 |
| PZA24M | 284,000 | 176.5 | 45.5 | 55 | 3490 | 4 | 6.0 |
| PZA30M | 370,400 | 176.5 | 88 | 55 | 3550 | 4 | 7.5 |
| PZA34M | 410,000 | 176.5 | 88 | 55 | 4850 | 4 | 8.5 |
| PZA42M | 494,000 | 176.5 | 88 | 55 | 4900 | 4 | 11.0 |
| PZA50M | 608,000 | 176.5 | 88 | 55 | 4950 | 4 | 13.0 |
| PZA60M | 730,000 | 230 | 88 | 57 | 7200 | 4 | 15.0 |
Packaged Air-Cooled Process Chillers with Stainless Steel Tank, Single and Dual Circuit Scroll
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressors | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| PZAT1S | 12,700 | 36 | 34 | 68 | 550 | 1 | 1.0 |
| PZAT2.5S | 25,800 | 36 | 34 | 68 | 650 | 1 | 2.5 |
| PZAT3.5S | 38,500 | 36 | 34 | 68 | 800 | 1 | 3.5 |
| PZAT4S | 45,300 | 36 | 34 | 68 | 825 | 1 | 4.0 |
| PZAT5S | 56,000 | 46 | 34 | 74 | 850 | 1 | 5.0 |
| PZAT5.5S | 62,800 | 46 | 34 | 74 | 875 | 1 | 5.5 |
| PZAT6S | 66,700 | 46 | 34 | 74 | 900 | 1 | 6.0 |
| PZAT7S | 55,200 | 75 | 34 | 76 | 1100 | 1 | 7.0 |
| PZAT8S | 96,400 | 75 | 34 | 76 | 1125 | 1 | 8.0 |
| PZAT10S | 116,000 | 75 | 34 | 76 | 1150 | 1 | 10.0 |
| PZAT12S | 143,000 | 75 | 34 | 76 | 1300 | 1 | 12.0 |
| PZAT15S | 171,500 | 75 | 34 | 76 | 1400 | 1 | 15.0 |
| PZAT8D | 90,600 | 75 | 34 | 76 | 1100 | 2 | 4.0 |
| PZAT10D | 112,000 | 75 | 34 | 76 | 1200 | 2 | 5.0 |
| PZAT11D | 125,600 | 75 | 34 | 76 | 1250 | 2 | 5.5 |
| PZAT12D | 133,400 | 75 | 34 | 76 | 1275 | 2 | 6.0 |
| PZAT15D | 174,000 | 85 | 40 | 76 | 1300 | 2 | 7.5 |
| PZAT17D | 192,800 | 85 | 40 | 76 | 1400 | 2 | 8.5 |
| PZAT21D | 232,000 | 75 | 66 | 76 | 2200 | 2 | 10.5 |
| PZAT25D | 286,000 | 75 | 66 | 76 | 2200 | 2 | 12.5 |
Tankless Air-Cooled Process Chillers, Split-System, Single and Dual Circuit Scroll
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressor | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| IEZA1S | 13,550 | 44 | 28 | 36 | 225 | 1 | 1.0 |
| IEZA2.5S | 27,500 | 44 | 28 | 36 | 370 | 1 | 2.5 |
| IEZA3.5S | 41,000 | 44 | 28 | 36 | 500 | 1 | 3.5 |
| IEZA4S | 48,300 | 44 | 28 | 36 | 525 | 1 | 4.0 |
| IEZA5S | 59,600 | 44 | 28 | 36 | 550 | 1 | 5.0 |
| IEZA5.5S | 66,800 | 44 | 28 | 36 | 575 | 1 | 5.5 |
| IEZA6S | 71,000 | 44 | 28 | 36 | 600 | 1 | 6.0 |
| IEZA7S | 92,600 | 44 | 28 | 36 | 700 | 1 | 7.0 |
| IEZA8S | 102,500 | 44 | 28 | 36 | 725 | 1 | 8.0 |
| IEZA10S | 123,500 | 44 | 28 | 36 | 750 | 1 | 10.0 |
| IEZA12S | 152,000 | 44 | 28 | 36 | 825 | 1 | 12.0 |
| IEZA15S | 182,500 | 44 | 28 | 36 | 850 | 1 | 15.0 |
| IEZA8D | 96,600 | 65 | 30 | 37 | 900 | 2 | 4.0 |
| IEZA10D | 119,200 | 65 | 30 | 37 | 1000 | 2 | 5.0 |
| IEZA11D | 133,600 | 65 | 30 | 37 | 1100 | 2 | 5.5 |
| IEZA12D | 142,000 | 65 | 30 | 37 | 1200 | 2 | 6.0 |
| IEZA15D | 185,200 | 65 | 30 | 37 | 1400 | 2 | 7.5 |
| IEZA17D | 205,000 | 65 | 30 | 37 | 1450 | 2 | 8.5 |
| IEZA21D | 247,000 | 65 | 30 | 37 | 1450 | 2 | 10.5 |
| IEZA25D | 304,000 | 85 | 34 | 42 | 1500 | 2 | 12.5 |
| IEZA30D | 365,000 | 85 | 34 | 42 | 1600 | 2 | 15.0 |
| IEZA16M | 193,200 | 85 | 34 | 42 | 1800 | 4 | 4.0 |
| IEZA20M | 238,400 | 85 | 34 | 42 | 1850 | 4 | 5.0 |
| IEZA24M | 284,000 | 85 | 34 | 45 | 1900 | 4 | 6.0 |
| IEZA30M | 370,400 | 85 | 34 | 45 | 2400 | 4 | 7.5 |
| IEZA34M | 410,000 | 85 | 34 | 45 | 2400 | 4 | 8.5 |
| IEZA42M | 494,000 | 85 | 34 | 45 | 2500 | 4 | 10.5 |
| IEZA50M | 608,000 | 85 | 34 | 45 | 2550 | 4 | 12.5 |
| IEZA60M | 730,000 | 85 | 34 | 45 | 3000 | 4 | 15.0 |
Split-System Air-Cooled Process Chillers with Stainless Steel Tank, Single and Dual Circuit Scroll
| Model Number | Nominal BTUH @ 45°F | Length (In.) | Width (In.) | Height (In.) | Weight | Compressor | |
|---|---|---|---|---|---|---|---|
| Qty. | HP | ||||||
| IEZAT1S | 12,700 | 36 | 34 | 65 | 550 | 1 | 1.0 |
| IEZAT2.5S | 25,800 | 36 | 34 | 65 | 650 | 1 | 2.5 |
| IEZAT3.5S | 38,500 | 36 | 34 | 65 | 800 | 1 | 3.5 |
| IEZAT4S | 45,300 | 36 | 34 | 65 | 825 | 1 | 4.0 |
| IEZAT5S | 56,000 | 46 | 34 | 69 | 850 | 1 | 5.0 |
| IEZAT5.5S | 62,800 | 46 | 34 | 69 | 875 | 1 | 5.5 |
| IEZAT6S | 66,700 | 46 | 34 | 69 | 900 | 1 | 6.0 |
| IEZAT7S | 87,000 | 75 | 34 | 70 | 1100 | 1 | 7.0 |
| IEZAT8S | 96,400 | 75 | 34 | 70 | 1150 | 1 | 8.0 |
| IEZAT10S | 116,000 | 75 | 34 | 70 | 1250 | 1 | 10.0 |
| IEZAT12S | 143,000 | 75 | 34 | 70 | 1300 | 1 | 12.0 |
| IEZAT15S | 171,500 | 75 | 34 | 70 | 1325 | 1 | 15.0 |
| IEZAT8D | 90,600 | 75 | 34 | 70 | 1350 | 2 | 4.0 |
| IEZAT10D | 112,000 | 75 | 34 | 70 | 1400 | 2 | 5.0 |
| IEZAT11D | 125,600 | 75 | 34 | 70 | 1450 | 2 | 5.5 |
| IEZAT12D | 133,400 | 75 | 34 | 70 | 1500 | 2 | 6.0 |
| IEZAT15D | 174,000 | 75 | 34 | 70 | 1700 | 2 | 7.5 |
| IEZAT17D | 192,800 | 85 | 34 | 70 | 1800 | 2 | 8.5 |
| IEZAT21D | 232,000 | 85 | 34 | 70 | 1900 | 2 | 10.5 |
| IEZAT25D | 286,000 | 85 | 34 | 70 | 2300 | 2 | 12.5 |
Note: Air-Cooled Process Chiller Capacities based on
ARI Standard 45ºF LWT and 95ºF AMB.
Ask about our process chillers.
Frequently asked questions about A2L air-cooled process chillers
What is a air-cooled chiller?
An A2L air-cooled chiller is a cooling unit that removes heat from a process and expells it out into open air. 1-6 condesner fans can operate different capacity loads based on the size of the unit and number of compressors. Unlike water-cooled units, these systems do not require a water tower or process water.
When to choose a air-cooled chiller?
Air-cooled chillers have simple installation, lower costs, and are ideal for when outdoor installation is preferred.
Primarily used for:
- Plastics Processing
- Medical and laboratory
- Mission critital situations
- Food and beverage processing
Why should I choose a Legacy Chillers, Inc. A2L air-cooled process chiller?
Our air-cooled units use refrigerants R-454A & R-454C. These refrigernats meet environmental regulations while maintaining optimal cooling performance. Air-cooled chillers operate outdoors, which means they are subjected to varying outdoor temperatures. Legacy air-cooled systems are fitted with the proper controls, condenser sizes, and fans to operate reliably in a wide range of climates.